That Pop off Valve is rated for 6000PSI. It is very easy to adjust the Pop Off Valve to the pressure of you
unit:
1. Screw the Allen head plug on the end of the Pop Off valve all
the way in (clockwise) till it stops.
2. Install the part on your machine.
3. Turn on the water, Start up your unit, and run it up to full
pressure.
5. Slowly unscrew (counter clockwise) the Allen head plug until
it Pops off.
6. Shut off the unit and turn off the water
7. Turn the Allen head plug back in (clockwise) 1/2 an turn
Now it should be set for the pressure of your unit. If it Pops
again you might have to give at an extra 1/4 turn (clockwise).