2/24/2021

ADJUSTING THE PRESSURE-Activated UNLOADER

                  


  pulsar/vrt3 and all pressure trapped

1. the adjusting nut is tightened to increase bypass pressure and loosened to decrease bypass pressure.

2. start with the machine off and the adjusting nut loosened (no tension on the spring). make sure the spray tip is correct for the volume (gpm) and operating pressure (psi).

3. install a pressure guage on pump discharge side of the pump head, or at the outlet where the pressure washer hose attaches.

4. start the machine with the trigger gun closed, the unit will bypass all the water flow from the unloader valve to the pump inlet.

5. with the machine running and the trigger gun now held open, adjust the unloader adjusting nut until the machine reaches the correct operating pressure per the machine specifications            (gpm and psi).

6. pull and then release the trigger gun several times, watching the guage and determine the spike pressure is no more than 200 psi above the operating pressure. adjust as necessary. tighten the lock nut to make the adjustment permanent.

7. make sure the spray tip is correct. remember to adjust the pressure spike to no more than 200 psi over the operating pressure.

8. tip changes – a green spray tip only indicates that it is a 25 degree tip. the tip size is the importan indicator. a 5.6 gpm machine at 35oo psi requires a # 6 tip size. the tip size is laser cut below the color coded plastic nozzle protector. a 2506 is correct for 5.6gpm@3500psi. Phone:833.400.0774 español: 800.917.9274 



2/18/2021

Hot-Water-Powerful-Commercial-132 Degree-Portable

 Water Cannon Exclusive Hot Water Pressure Washers deliver 4.0GPM and 4000PSI and a 132 degree temperature rise, this pressure washing unit will get the job done. Each model comes with all the necessary accessories for you to get started right away. To protect your investment there is a 3 Year Warranty on the engine and 2 Year Warranties on the Pump and Frame!

 

EK or General Pump Triplex Plunger Pump

Inline Serviceable Stainless Steel Mesh Water Filter

Oil Bath Crank Case with dipstick and sight gauge

Stainless Unitized Valves


Forged Brass Manifold

Thermo Pump Protector engages at 140 Degrees F

Adjustable Pressure Regulator from 150psi to max

Fully Welded Powder Coated Steel Frame


Phone: 833.400.0774
Espanol: 800.917.9274

2/11/2021

Zebra stripping and can be caused from 4 areas of concern.

 


This is called Zebra stripping and can be caused from 4 areas of concern. Flip cover over and check fan Pattern to make sure you are getting full spray

Out of each nozzle.

Sometimes when you connect garden hose to pressure washer you can pick up Debris and will make its way to the nozzle and will cause this issue from partial fan spray coming out.

Remove the nozzle with 9/16 socket and use air compressor or tooth pick And clear orifice of Tips.

Before installing the tips back, Run water through the system/bar until all
Debris are gone then install tips back with cavity line across face of tip runs
Parallel with spray bar.

2nd Cause of issue would be too low of pressure coming from pressure washer
Check the pressure with a gauge to confirm the unit is putting out correct pressure.

3rd Cause if unit hits anything extruded from ground or roof tops will cause
The Tips to move out of position or damage to bearings wiggle bar
side to side to see if excessive play Make sure cavity line of tips are parallel with bar.

4th cause of issue If system hits anything from rocks to extruded areas will cause 1
of the spring loaded seats to move out of position and allow pressure to Escape out
and around seat and cut the small o-ring and  back up nylon seal and will lose pressure
through weep hole at  Bottom of cover. Will need to replace seal kit.

833.400.0774
Espanol: 800.917.9274